High Voltage Multiplier - A generic Selection

 

 

 

 

 

 

Type: K

HV-Cascades
without
integrated
HV-Transformer

REMO-HSE Circuit board mountable  9kV multiplier

REMO-HSE High voltage multiplier 12kV & 6kV

REMO-HSE High voltage multiplier 30kV

Positive Polarity

K-2.3k-9k-70

K-2.3k-12.5/6.2k-10m

K-3k-30k-5m

Negative Polarity

K-2.3k-(-9k)-70

K-2.3k-(-12.5/-6.2k)-10m

K-3k-(-30k)-5m

No. of HV-Outputs

1

2

2

Input Voltage

2,3 kVss

2,3 kVss

8,3 kVss

Operating Frequency

<200 kHz

<200 kHz

<200 kHz

HV Output U1

9 kV

12,5 kV

30 kV

HV Output U2

 

6,25 kV

30 kV

Total Output Current

70 A

10 mA

5 mA

Monitoring Outputs

-

2

2

Protective Resistance

-

 

45,5 kOhm

Ambient Temperature

0 ... 45C

0 ... 45C

0 ... 45C

Dimensions (LxWxH)

35 26 26 mm

85 50 41 mm

110 70,5 47 mm

Weight

44g

320g

540g

 

 

 

 

 

Type: K

HV-Cascades
 without
integrated
HV-Transformer

REMO-HSE High voltage multiplier 60kV

REMO-HSE High voltage multiplier 120kV

REMO-HSE High voltage multiplier 30kV

Positive Polarity

K-3.3k-60k-2.5m-KNH65

K-4.53k-120k-1.25m

K-3k-30k-25m

Negative Polarity

K-3.3k-(-60k)-2.5m-KNH-65

K-4.5k-(-120k)-1.25m

K-3k-(-30k)-25m

No. of HV-Outputs

2

1

4

Input Voltage

3,3 kVss

<10 kVss

<8 kVss

Operating Frequency

<200 kHz

<200 kHz

<200 kHz

HV Output U1

60 kV

120 kV

30 kV

HV Output U2

 

 

 

Total Output Current

2.5 mA

1,25 mA

25 mA

Monitoring Outputs

2

2

2

Protective Resistance

445 kOhm

900 kOhm

2,31 kOhm

Ambient Temperature

0 ... 45C

0 ... 45C

0 ... 45C

Dimensions (LxWxH)

160 95 75 mm

328.5 211.5 70 mm

184 124 60 mm

Weight

1.8 kg

8,8 kg

2,2 kg

 

 

 

 

 

Type: TK

HV-Cascades
with
integrated
HV-Transformer

REMO-HSE High voltage transformer & multiplier 100k

REMO-HSE High voltage transformer & multiplier 70k

REMO-HSE High voltage transformer & multiplier 25kV

Positive Polarity

TK-30-100k-100

TK-24-70k-100

TK-24-30k-200

Negative Polarity

TK-30-(-100k)-100

TK-24-(-70k)-100

TK-24-(-30k)-200

No. of HV-Outputs

1

1

1

Input Voltage

max. 30V

max. 24V

max. 24V

Operating Frequency

<200 kHz

<200 kHz

<200 kHz

HV Output U1

93 kV

70 kV

30 kV

HV Output U2

 

 

 

Total Output Current

100 A

100 A

200 A

Monitoring Outputs

1

1

2

Protective Resistance

75 MOhm

75 MOhm

10 MOhm

Ambient Temperature

0 ... 45C

0 ... 45C

0 ... 45C

Dimensions (LxWxH)

195 mm,  25 mm

234,5 33 30.6 mm

149 35 33 mm

Weight

44 g

300 g

300 g

 

 


 

 